Date: 2013
Language: eng
Resource Type: conference paper
Identifier: http://hdl.handle.net/1959.14/291631
Description: Microfluidic particle separation technologies are useful for enriching rare cell populations for academic and clinical purposes. In order to separate particles based on size, deterministic lateral dis ... More
Reviewed: Reviewed
Date: 2013
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/272259
Description: Deterministic lateral displacement (DLD) is a microfluidic size-based particle separation or filter technology with applications in cell separation and enrichment. Currently, there are no cost-effecti ... More
Full Text: Full Text
Reviewed: Reviewed
Date: 2013
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/231729
Description: We demonstrate matrix-free pH gradient electrofocusing of proteins within an 85 nm deep nanochannel. In contrast to conventional isoelectric focusing where the fluid does not move, this pH gradient me ... More
Reviewed: Reviewed
Date: 2011
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/160251
Description: A disposable device for fractionation of blood into its components that is simple to operate and provides throughput of greater than 1 mL min-1 is highly sought after in medical diagnostics and therap ... More
Reviewed: Reviewed
Date: 2011
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/143196
Description: Balancing the forces: Conductivity gradient focusing in a nanochannel achieves simultaneous separation and concentration of proteins without a temperature gradient, membrane, matrix, ampholytes, or ex ... More
Reviewed: Reviewed
Authors: Inglis, David W
Date: 2010
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/119983
Description: Poly(dimethylsiloxane) or PDMS is an excellent material for replica molding, widely used in microfluidics research. Its low elastic modulus, or high deformability, assists its release from challenging ... More
Full Text: Full Text
Reviewed: Reviewed
Date: 2010
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/124945
Description: We have designed, built, and evaluated a microfluidic device that uses deterministic lateral displacement for size-based separation. The device achieves almost 100% purity and recovery in continuously ... More
Full Text: Full Text
Reviewed: Reviewed
Authors: Inglis, David W
Date: 2009
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/124952
Description: Microfluidic particle separation arrays are capable of passive sorting of microparticles or cells by size while avoiding blockage. Despite the usefulness of boundaries for concentration and parallel i ... More
Full Text: Full Text
Reviewed: Reviewed
Date: 2008
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/125039
Description: We present a versatile method for continuous-flow, on-chip biological processing of cells, large bio-particles, and functional beads. Using an asymmetric post array in pressure-driven microfluidic flo ... More
Reviewed: Reviewed
Date: 2008
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/124962
Description: Microfluidic flow cytometers currently analyze far fewer parameters than conventional flow cytometry or fluorescence activated cell sorting (FACS) in order to minimize cost and complexity. There is a ... More
Reviewed: Reviewed
Date: 2008
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/125045
Description: We show that it is possible to direct particles entrained in a fluid along trajectories much like rays of light in classical optics. A microstructured, asymmetric post array forms the core hydrodynami ... More
Reviewed: Reviewed
Date: 2008
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/125040
Description: In this work we demonstrate a new microfluidic method for the rapid assessment of platelet size and morphology in whole blood. The device continuously fractionates particles according to size by displ ... More
Reviewed: Reviewed
Date: 2006
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/125046
Description: We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic ... More
Reviewed: Reviewed
Date: 2006
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/125053
Description: Separation of blood cells by native susceptibility and by the selective attachment of magnetic beads has recently been demonstrated on microfluidic devices. We discuss the basic principles of how forc ... More
Full Text: Full Text
Reviewed: Reviewed
Date: 2004
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/124956
Description: We present a continuous-flow microfluidic device that enables cell by cell separation of cells selectively tagged with magnetic nanoparticles. The cells flow over an array of microfabricated magnetic ... More