Date: 2013
Subject Keyword: 110300 Clinical Sciences
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/274666
Description: Reduced ocular perfusion pressure has been linked to glaucoma, and increased arterial stiffness is implicated in systemic cardiovascular risk. This study measured central blood pressure (BP) and arter ... More
Reviewed: Reviewed
Date: 2012
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/314755
Description: Background: Glaucoma is a sight-threatening disease affecting 3% of the population over the age of 50. Glaucoma is treatable, and severe vision loss can usually be prevented if diagnosis is made at an ... More
Reviewed: Reviewed
Date: 2011
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/152210
Description: The aims of this study were to evaluate and improve the reproducibility of visual evoked potential (VEP) measurement in rats and to develop a mini-Ganzfeld stimulator for rat VEP recording. VEPs of Sp ... More
Reviewed: Reviewed
Date: 2010
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117180
Description: Optic neuritis provides an in vivo model to study demyelination. The effects of myelin loss and recovery can be measured by the latency of the multifocal visual evoked potentials. We investigated whet ... More
Reviewed: Reviewed
Date: 2007
Subject Keyword: 110300 Clinical Sciences
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117366
Description: Objective: To determine the sensitivity and specificity of blue-on-yellow multifocal visual evoked potentials (mfVEPs) in early glaucoma. Design: Cross-sectional study. Participants: Fifty patients wi ... More
Reviewed: Reviewed
Date: 2006
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/116986
Description: Purpose: To compare sensitivity and specificity of functional and structural changes in glaucoma using two objective tests: the multifocal visual evoked potential (m-VEP) and Heidelberg retinal tomogr ... More
Reviewed: Reviewed
Date: 2006
Subject Keyword: 110300 Clinical Sciences
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117392
Description: Objective: To determine the sensitivity of multifocal visual evoked potentials (mVEP) in optic neuritis of an inflammatory or demyelinating nature. Design: Cross-sectional study. Participants: Sixty-f ... More
Reviewed: Reviewed
Date: 2006
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117398
Description: Objective: To monitor the difference in conversion rates to multiple sclerosis (MS) in 46 patients with optic neuritis between patients with multifocal visual evoked potential latency delay and those ... More
Reviewed: Reviewed
Date: 2006
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117397
Description: Multifocal visual evoked potentials (mfVEPs) have demonstrated good diagnostic capabilities in glaucoma and optic neuritis. This study aimed at evaluating the possibility of simultaneously recording m ... More
Reviewed: Reviewed
Date: 2005
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117145
Description: Purpose: The sparse pattern-pulse stimulation has been suggested to produce better cortical evoked responses compared to pattern reversal stimulation. This study examines varying pattern-pulse states ... More
Reviewed: Reviewed
Date: 2005
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117148
Description: Purpose:  This study investigated the effects of cognitive influence on the multifocal visual evoked potential (mVEP) at different levels of eccentricity. Three different foveal fixation conditions we ... More
Reviewed: Reviewed
Date: 2005
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117365
Description: Purpose: The multi-focal visual evoked potential (mfVEP) has been recently introduced as an alternative to subjective perimetry in detecting visual field defects. This study examines the source of var ... More
Reviewed: Reviewed
Date: 2005
Subject Keyword: 110300 Clinical Sciences
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117414
Description: Aims: To examine the ability of the multifocal pattern visual evoked potential (mVEP) to detect field loss in neurological lesions affecting the visual pathway from the chiasm to the cortex. Method: T ... More
Reviewed: Reviewed
Date: 2003
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117151
Description: The purpose of this study was to investigate the influence of pupil diameter on the amplitude and latency of multifocal visual evoked potentials (mfVEP). The multifocal objective perimeter (Accumap; O ... More
Reviewed: Reviewed
Date: 2003
Language: eng
Resource Type: journal article
Identifier: http://hdl.handle.net/1959.14/117154
Description: In this study we examined the effects of varying stimulus check size on multifocal visual evoked potential (VEP). We also evaluated the currently used cortical scaling of stimulus segments. The Object ... More